123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212 |
- Advanced usage instructions for the Independent JPEG Group's JPEG software
- ==========================================================================
- This file describes cjpeg's "switches for wizards".
- The "wizard" switches are intended for experimentation with JPEG by persons
- who are reasonably knowledgeable about the JPEG standard. If you don't know
- what you are doing, DON'T USE THESE SWITCHES. You'll likely produce files
- with worse image quality and/or poorer compression than you'd get from the
- default settings. Furthermore, these switches must be used with caution
- when making files intended for general use, because not all JPEG decoders
- will support unusual JPEG parameter settings.
- Quantization Table Adjustment
- -----------------------------
- Ordinarily, cjpeg starts with a default set of tables (the same ones given
- as examples in the JPEG standard) and scales them up or down according to
- the -quality setting. The details of the scaling algorithm can be found in
- jcparam.c. At very low quality settings, some quantization table entries
- can get scaled up to values exceeding 255. Although 2-byte quantization
- values are supported by the IJG software, this feature is not in baseline
- JPEG and is not supported by all implementations. If you need to ensure
- wide compatibility of low-quality files, you can constrain the scaled
- quantization values to no more than 255 by giving the -baseline switch.
- Note that use of -baseline will result in poorer quality for the same file
- size, since more bits than necessary are expended on higher AC coefficients.
- You can substitute a different set of quantization values by using the
- -qtables switch:
- -qtables file Use the quantization tables given in the named file.
- The specified file should be a text file containing decimal quantization
- values. The file should contain one to four tables, each of 64 elements.
- The tables are implicitly numbered 0,1,etc. in order of appearance. Table
- entries appear in normal array order (NOT in the zigzag order in which they
- will be stored in the JPEG file).
- Quantization table files are free format, in that arbitrary whitespace can
- appear between numbers. Also, comments can be included: a comment starts
- with '#' and extends to the end of the line. Here is an example file that
- duplicates the default quantization tables:
- # Quantization tables given in Annex K (Clause K.1) of
- # Recommendation ITU-T T.81 (1992) | ISO/IEC 10918-1:1994.
- # This is table 0 (the luminance table):
- 16 11 10 16 24 40 51 61
- 12 12 14 19 26 58 60 55
- 14 13 16 24 40 57 69 56
- 14 17 22 29 51 87 80 62
- 18 22 37 56 68 109 103 77
- 24 35 55 64 81 104 113 92
- 49 64 78 87 103 121 120 101
- 72 92 95 98 112 100 103 99
- # This is table 1 (the chrominance table):
- 17 18 24 47 99 99 99 99
- 18 21 26 66 99 99 99 99
- 24 26 56 99 99 99 99 99
- 47 66 99 99 99 99 99 99
- 99 99 99 99 99 99 99 99
- 99 99 99 99 99 99 99 99
- 99 99 99 99 99 99 99 99
- 99 99 99 99 99 99 99 99
- If the -qtables switch is used without -quality, then the specified tables
- are used exactly as-is. If both -qtables and -quality are used, then the
- tables taken from the file are scaled in the same fashion that the default
- tables would be scaled for that quality setting. If -baseline appears, then
- the quantization values are constrained to the range 1-255.
- By default, cjpeg will use quantization table 0 for luminance components and
- table 1 for chrominance components. To override this choice, use the -qslots
- switch:
- -qslots N[,...] Select which quantization table to use for
- each color component.
- The -qslots switch specifies a quantization table number for each color
- component, in the order in which the components appear in the JPEG SOF marker.
- For example, to create a separate table for each of Y,Cb,Cr, you could
- provide a -qtables file that defines three quantization tables and say
- "-qslots 0,1,2". If -qslots gives fewer table numbers than there are color
- components, then the last table number is repeated as necessary.
- Sampling Factor Adjustment
- --------------------------
- By default, cjpeg uses 2:1 horizontal and vertical downsampling when
- compressing YCbCr data, and no downsampling for all other color spaces.
- You can override this default with the -sample switch:
- -sample HxV[,...] Set JPEG sampling factors for each color
- component.
- The -sample switch specifies the JPEG sampling factors for each color
- component, in the order in which they appear in the JPEG SOF marker.
- If you specify fewer HxV pairs than there are components, the remaining
- components are set to 1x1 sampling. For example, the default YCbCr setting
- is equivalent to "-sample 2x2,1x1,1x1", which can be abbreviated to
- "-sample 2x2".
- There are still some JPEG decoders in existence that support only 2x1
- sampling (also called 4:2:2 sampling). Compatibility with such decoders can
- be achieved by specifying "-sample 2x1". This is not recommended unless
- really necessary, since it increases file size and encoding/decoding time
- with very little quality gain.
- Multiple Scan / Progression Control
- -----------------------------------
- By default, cjpeg emits a single-scan sequential JPEG file. The
- -progressive switch generates a progressive JPEG file using a default series
- of progression parameters. You can create multiple-scan sequential JPEG
- files or progressive JPEG files with custom progression parameters by using
- the -scans switch:
- -scans file Use the scan sequence given in the named file.
- The specified file should be a text file containing a "scan script".
- The script specifies the contents and ordering of the scans to be emitted.
- Each entry in the script defines one scan. A scan definition specifies
- the components to be included in the scan, and for progressive JPEG it also
- specifies the progression parameters Ss,Se,Ah,Al for the scan. Scan
- definitions are separated by semicolons (';'). A semicolon after the last
- scan definition is optional.
- Each scan definition contains one to four component indexes, optionally
- followed by a colon (':') and the four progressive-JPEG parameters. The
- component indexes denote which color component(s) are to be transmitted in
- the scan. Components are numbered in the order in which they appear in the
- JPEG SOF marker, with the first component being numbered 0. (Note that these
- indexes are not the "component ID" codes assigned to the components, just
- positional indexes.)
- The progression parameters for each scan are:
- Ss Zigzag index of first coefficient included in scan
- Se Zigzag index of last coefficient included in scan
- Ah Zero for first scan of a coefficient, else Al of prior scan
- Al Successive approximation low bit position for scan
- If the progression parameters are omitted, the values 0,63,0,0 are used,
- producing a sequential JPEG file. cjpeg automatically determines whether
- the script represents a progressive or sequential file, by observing whether
- Ss and Se values other than 0 and 63 appear. (The -progressive switch is
- not needed to specify this; in fact, it is ignored when -scans appears.)
- The scan script must meet the JPEG restrictions on progression sequences.
- (cjpeg checks that the spec's requirements are obeyed.)
- Scan script files are free format, in that arbitrary whitespace can appear
- between numbers and around punctuation. Also, comments can be included: a
- comment starts with '#' and extends to the end of the line. For additional
- legibility, commas or dashes can be placed between values. (Actually, any
- single punctuation character other than ':' or ';' can be inserted.) For
- example, the following two scan definitions are equivalent:
- 0 1 2: 0 63 0 0;
- 0,1,2 : 0-63, 0,0 ;
- Here is an example of a scan script that generates a partially interleaved
- sequential JPEG file:
- 0; # Y only in first scan
- 1 2; # Cb and Cr in second scan
- Here is an example of a progressive scan script using only spectral selection
- (no successive approximation):
- # Interleaved DC scan for Y,Cb,Cr:
- 0,1,2: 0-0, 0, 0 ;
- # AC scans:
- 0: 1-2, 0, 0 ; # First two Y AC coefficients
- 0: 3-5, 0, 0 ; # Three more
- 1: 1-63, 0, 0 ; # All AC coefficients for Cb
- 2: 1-63, 0, 0 ; # All AC coefficients for Cr
- 0: 6-9, 0, 0 ; # More Y coefficients
- 0: 10-63, 0, 0 ; # Remaining Y coefficients
- Here is an example of a successive-approximation script. This is equivalent
- to the default script used by "cjpeg -progressive" for YCbCr images:
- # Initial DC scan for Y,Cb,Cr (lowest bit not sent)
- 0,1,2: 0-0, 0, 1 ;
- # First AC scan: send first 5 Y AC coefficients, minus 2 lowest bits:
- 0: 1-5, 0, 2 ;
- # Send all Cr,Cb AC coefficients, minus lowest bit:
- # (chroma data is usually too small to be worth subdividing further;
- # but note we send Cr first since eye is least sensitive to Cb)
- 2: 1-63, 0, 1 ;
- 1: 1-63, 0, 1 ;
- # Send remaining Y AC coefficients, minus 2 lowest bits:
- 0: 6-63, 0, 2 ;
- # Send next-to-lowest bit of all Y AC coefficients:
- 0: 1-63, 2, 1 ;
- # At this point we've sent all but the lowest bit of all coefficients.
- # Send lowest bit of DC coefficients
- 0,1,2: 0-0, 1, 0 ;
- # Send lowest bit of AC coefficients
- 2: 1-63, 1, 0 ;
- 1: 1-63, 1, 0 ;
- # Y AC lowest bit scan is last; it's usually the largest scan
- 0: 1-63, 1, 0 ;
- It may be worth pointing out that this script is tuned for quality settings
- of around 50 to 75. For lower quality settings, you'd probably want to use
- a script with fewer stages of successive approximation (otherwise the
- initial scans will be really bad). For higher quality settings, you might
- want to use more stages of successive approximation (so that the initial
- scans are not too large).
|